 Methane filling stations (CNG)
Gas filling station can be easily deployed in small area for filling of vehicles, buses and other technics. Filling station can be placed near roads and main traffic artery as well as in the territory of the company by using compressors with lower efficiency.
The working principle of gas filing station is based on complicated technology of gas preparation.
Initially station is plugged to gas and electricity line. As a gas source gas grid, biogas treatment system or accumulation blocks (virtual gas line system) are used. The accumulation blocks can be easily transported to their filling place as they are of modular execution.
 |
 |
| Gas accumulation module |
Dispenser |
Gas is supplied from the source and can be initially dried or purified from admixtures. After that gas is compressed to operational pressure and supplied to accumulation block where constant gas volume is supported. From the accumulation block gas is filled into the vehicles tanks and is ready to be used as fuel. In case of heavy vehicles traffic gas can be supplied directly from the compressor. Filling station is deployed to the concrete base.
In case filling station is made in container module, capital structures are not required, only concrete ground should be prepared. Water for technological purposes is not required, compressor has air cooling.
Gas filling station works in automatic mode. Automatics system provides all station parameters control, station switch on and off in case of any emergency. Station monitoring system allows control the station via GSM channel by transmitting current operational information and problems. Station equipment is made in explosion proof execution. Gas filling station also equipped with safety system consisting of gas control, fire emergency and automatic fire fight module.
 |
|
| Compressor station |
Compressor station |
As per customers request filling station can be equipped with remote control of control panel. Optionally compression unit and all systems can be executed in container for outdoor usage with heating, container is explosion and noise proof.
Characteristics
| Characteristics |
Model 1
|
Model 2
|
Model 3 |
Model 4 |
Ìîäåëü 5
|
Inlet pressure, bar
|
1,5 — 5,0
|
0,2 — 0,9
|
1,4 — 3,0
|
0,2 — 1,1
|
0,8 — 4,0 |
| Motor capacity, kW |
90 |
90 |
444 |
633 |
963 |
| Efficiency, m3/h |
225 |
450 |
178 |
255 |
387 |
| Accumulation module volume, liters |
2500
|
| Compression stages
|
4 |
5
|
4
|
5
|
5
|
| Outlet pressure, bar |
250 |