1 / 2
Biogas blower E-12-TD — 22 kW, 900 m³/h at 250 mbar

Biogas blower E-12-TD — 22 kW, 900 m³/h at 250 mbar

Gases and purpose

The blower supplies and increases the pressure of biogas, biomethane, landfill gas, sewage gas, natural gas, air, CO₂ and synthesis gas.

Blower applications

Booster supply of biogas and biomethane through long pipelines with many bends and valves. Pressure boosting before biogas upgrading modules and across gas-treatment sections with high resistance.

Technical specifications
Features
Parameter50 Hz60 Hz
Maximum flow, m³/h10531249
Maximum gauge pressure, mbar500350
Motor power, kW2222
Sound level at 1 m, dB(A)8486
Blower weight without motor, kg139139
MotorTwo-pole, IECTwo-pole, IEC
Blower ATEX ratingII 3GD T3II 3GD T3
Flexible coupling ATEX ratingII 2GDII 2GD
Blower operating points
Gauge pressure, mbarFlow at 50 Hz, m³/hFlow at 60 Hz, m³/h
2009401140
3008801090
400830—
500770—

“—” means the pressure is outside the operating range of this motor at the specified frequency. Flow rates at the stated pressures refer to air at 20 °C and an absolute inlet pressure of 1013 mbar. They can be used as indicative values for biogas of similar density. For methane, at the same volumetric flow and speed, the pressure difference is lower, approximately in proportion to the methane-to-air density ratio under the same inlet conditions.

Technical specifications
Parameter50 Hz60 Hz
Maximum flow, m³/h10531249
Maximum gauge pressure, mbar500350
Motor power, kW2222
Sound level at 1 m, dB(A)8486
Blower weight without motor, kg139139
MotorTwo-pole, IECTwo-pole, IEC
Blower ATEX ratingII 3GD T3II 3GD T3
Flexible coupling ATEX ratingII 2GDII 2GD
Blower operating points
Gauge pressure, mbarFlow at 50 Hz, m³/hFlow at 60 Hz, m³/h
2009401140
3008801090
400830—
500770—

“—” means the pressure is outside the operating range of this motor at the specified frequency. Flow rates at the stated pressures refer to air at 20 °C and an absolute inlet pressure of 1013 mbar. They can be used as indicative values for biogas of similar density. For methane, at the same volumetric flow and speed, the pressure difference is lower, approximately in proportion to the methane-to-air density ratio under the same inlet conditions.

Features

Two impellers operate in series: gas leaving the first stage enters the second for further compression. Each stage is based on an MS module with two parallel side channels. The motor drives the blower through a flexible coupling. The housing and impellers are made of lightweight aluminium alloy. A protective oxide film forms on the aluminium surface.