Biogas chiller 100 m³/h (35-5)

Biogas flow: 100 m3/h
Inlet temperature     [°C] 35
Outlet temperature [°C] 5
Relative humidity at inlet [%] 100
Relative humidity at outlet (before reheater) [%] 100
Pressure loss (+3 mbar at demister)         [mbar] 10
Operating pressure [bar(ü)]      0
min. operating pressure [bar(ü)] -0,2
max. operating pressure [bar(ü)] 0,5
Required cooling power [kW] 5,4
Power supply 430V/3 phase/50Hz
Condensate removal [kg/h]       5

COOLING MACHINE

Installed cooling power [kW] 5,4
At ambient temperature [°C] 32
Inlet temperature cooling circuit [°C] 5
Outlet temperature cooling circuit [°C] 1
Cooling media R-410A
Rated power consumption including pump and fan [kW]           2,3
max. current consumption        [A] 6,8
max. starting current [A] 33,3
Power supply 440V/3 phase/50Hz
Cold brine buffer storage           [ltr.] 30
Sound pressure level in 10 m distance (+/- 2 dB(A)) [dB(A)] 30

INSTALLATION & CONNECTIONS

Installation site                          
Outdoor installation; No ex zone
max. installation altitude          m.a.s.l.     500
min. ambient temperature         [°C]           -20
max. ambient            [°C]           42
Inlet connection:       [DN/PN]    100/6
Outlet connection     [DN/PN]    100/6
Condensate drain      R1"
Condensate drain with condensate accumulator G 1/2"

DIMENSIONS

Length [mm] 2700
Width [mm] 1400
Height [mm] 1500
Transport weight [kg] 600
Operation weight [kg] 800

SCOPE OF SUPPLY:
Gas cooler
Air-cooled liquid chiller (eurovent certified)
Base frame for gas dehumidifier
Insulation of the gas cooler
Demister
Syphon for condensate removal
Collection vessel with pump
Glycol

OPTIONS:

- control panel (including the panel itself, design, cabling, programming, connections) with 1x temperature sensor and 1x pressure sensor, connected Protection class IP55
- making the heat exchanger shell&base frame in 316 stainless steel

Technical Details
Features
Optional Features

Gas flow rate:

100 Nm³/h

H₂S content:

up to 20,000 ppm (2.0 vol%)

Gas temperature at inlet:

up to 35 °C

Gas temperature at outlet:

down to 5 °C

Gas pressure at inlet:

-100 to +500 mbar

Ambient temperature:

-20°C to +45°C

Technical Details

Gas flow rate:

100 Nm³/h

H₂S content:

up to 20,000 ppm (2.0 vol%)

Gas temperature at inlet:

up to 35 °C

Gas temperature at outlet:

down to 5 °C

Gas pressure at inlet:

-100 to +500 mbar

Ambient temperature:

-20°C to +45°C

Features

Components in contact with gas made from 11.4404/1.4571 stainless steel

Condensate removal via siphon or pressure-independent with pump

Improved efficiency and protection for gas engines and CHP stations

Simple operation

Optional Features
  • Special designs are available on request
  • Optionally with reheating
  • Optional with pre-chilling stage for energy savings

Other goods

Activated charcoal filter 600 m³/h
Activated charcoal filter 220 m³/h
Activated charcoal filter 160 m³/h
Activated charcoal filter 100 m³/h