Biogas chiller 100 m³/h (35-5)
€ 32.500,00
Biogas flow: 100 m3/h
Inlet temperature [°C] 35
Outlet temperature [°C] 5
Relative humidity at inlet [%] 100
Relative humidity at outlet (before reheater) [%] 100
Pressure loss (+3 mbar at demister) [mbar] 10
Operating pressure [bar(ü)] 0
min. operating pressure [bar(ü)] -0,2
max. operating pressure [bar(ü)] 0,5
Required cooling power [kW] 5,4
Power supply 430V/3 phase/50Hz
Condensate removal [kg/h] 5
COOLING MACHINE
Installed cooling power [kW] 5,4
At ambient temperature [°C] 32
Inlet temperature cooling circuit [°C] 5
Outlet temperature cooling circuit [°C] 1
Cooling media R-410A
Rated power consumption including pump and fan [kW] 2,3
max. current consumption [A] 6,8
max. starting current [A] 33,3
Power supply 440V/3 phase/50Hz
Cold brine buffer storage [ltr.] 30
Sound pressure level in 10 m distance (+/- 2 dB(A)) [dB(A)] 30
INSTALLATION & CONNECTIONS
Installation site
Outdoor installation; No ex zone
max. installation altitude m.a.s.l. 500
min. ambient temperature [°C] -20
max. ambient [°C] 42
Inlet connection: [DN/PN] 100/6
Outlet connection [DN/PN] 100/6
Condensate drain R1"
Condensate drain with condensate accumulator G 1/2"
DIMENSIONS
Length [mm] 2700
Width [mm] 1400
Height [mm] 1500
Transport weight [kg] 600
Operation weight [kg] 800
SCOPE OF SUPPLY:
Gas cooler
Air-cooled liquid chiller (eurovent certified)
Base frame for gas dehumidifier
Insulation of the gas cooler
Demister
Syphon for condensate removal
Collection vessel with pump
Glycol
OPTIONS:
- control panel (including the panel itself, design, cabling, programming, connections) with 1x temperature sensor and 1x pressure sensor, connected Protection class IP55
- making the heat exchanger shell&base frame in 316 stainless steel
Technical Details
Features
Optional Features
Gas flow rate:
100 Nm³/h
H₂S content:
up to 20,000 ppm (2.0 vol%)
Gas temperature at inlet:
up to 35 °C
Gas temperature at outlet:
down to 5 °C
Gas pressure at inlet:
-100 to +500 mbar
Ambient temperature:
-20°C to +45°C
Technical Details
Gas flow rate:
100 Nm³/h
H₂S content:
up to 20,000 ppm (2.0 vol%)
Gas temperature at inlet:
up to 35 °C
Gas temperature at outlet:
down to 5 °C
Gas pressure at inlet:
-100 to +500 mbar
Ambient temperature:
-20°C to +45°C