Due to the constant measurement of the biogas composition in the flow, gas sensors must be of a special design and withstand the aggressive environment exposure. The use of a gas analyzer is recommended at most biogas plants with frequently changed raw materials. Without exact knowledge of the biogas composition, a generator will not be able to determine the optimal composition of the fuel-air mixture.

Technical Details
Features

Measuring ranges:

CH₄: 0 to 100 Vol.%, CO₂: 0 to 100 Vol.%, O₂: 0 to 25 Vol.%, H₂S: 0 to 5,000 ppm, others on request

Designs for the detection of different gases possible:

SSM 6000 Classic (CH₄, H₂S), SSM 6000 Classic (CH₄, H₂S, O₂), SSM 6000 Classic (CH₄, H₂S, O₂, CO₂)

Wall construction

or table housing, 19”/3 height units, sub-racks 84 partial units

Display and measured value displays:

4-digit LED display of measured values, status indicators for each reading, 4-digit illuminated LCD for each measured value

Power supply:

230 VAC / 50 Hz; Option: 115 VAC / 60 Hz

Analogue outputs:

4–20 mA (one output per measured component)

Digital outputs:

12 units / functions, such as status signals, limit alarms, configurable measuring point switching

Digital inputs:

4 units / functions

Data storage

with history function of approximately 6,500 values; output via RS 232; also readable on the display

Interfaces:

RS 232, digital output of the measured values and program updates; Option: Profibus DP / CAN-bus

Further specifications

on request

Technical Details

Measuring ranges:

CH₄: 0 to 100 Vol.%, CO₂: 0 to 100 Vol.%, O₂: 0 to 25 Vol.%, H₂S: 0 to 5,000 ppm, others on request

Designs for the detection of different gases possible:

SSM 6000 Classic (CH₄, H₂S), SSM 6000 Classic (CH₄, H₂S, O₂), SSM 6000 Classic (CH₄, H₂S, O₂, CO₂)

Wall construction

or table housing, 19”/3 height units, sub-racks 84 partial units

Display and measured value displays:

4-digit LED display of measured values, status indicators for each reading, 4-digit illuminated LCD for each measured value

Power supply:

230 VAC / 50 Hz; Option: 115 VAC / 60 Hz

Analogue outputs:

4–20 mA (one output per measured component)

Digital outputs:

12 units / functions, such as status signals, limit alarms, configurable measuring point switching

Digital inputs:

4 units / functions

Data storage

with history function of approximately 6,500 values; output via RS 232; also readable on the display

Interfaces:

RS 232, digital output of the measured values and program updates; Option: Profibus DP / CAN-bus

Further specifications

on request

Features

High quality measurement components and methods:

an infra-red measuring process is used to detect methane (CH₄) and carbon dioxide (CO₂) with high accuracy and selectivity. This process eliminates any dependencies that pressure and temperature could have on the measured values;

hydrogen sulphide (H₂S) and hydrogen (H₂) are detected by electrochemical sensors;

oxygen (O₂) is predominantly measured using electrochemical sensors. Paramagnetic measuring cells are used for special requirements – particularly in conjunction with upgrading biogas to biomethane so that it can be used to supply the public grid.

Excellent long-term stability during methane and carbon dioxide measurements ensured by special technology.