Biogas analyzer SSM 6000 Classic for hot region

Multi-channel measuring instrument for biogas, landfill gas, biomethane with built-in gas processing, for use in hot climates (+50 °C). The gas analyzer can control up to eight measuring points and the analysis is fully automatic and can be carried out at variable time intervals. It features a data storage with a history function that records the specific time for all measured values.
The gas analyzer can be installed outdoors in a special housing as well as indoors.

Technical Details
Features

Measuring ranges:

CH₄: 0 to 100 Vol.%, CO₂: 0 to 100 Vol.%, O₂: 0 to 25 Vol.%, H₂S: 0 to 5,000 ppm, others on request

Designs for the detection of different gases possible:

SSM 6000 Classic (CH₄, H₂S), SSM 6000 Classic (CH₄, H₂S, O₂), SSM 6000 Classic (CH₄, H₂S, O₂, CO₂)

Wall construction

or table housing 19”/3 height units, sub-racks 84 partial units

Display and measured value displays:

4-digit LED display of measured values, status indicators for each reading, 4-digit illuminated LCD for each measured value

Power supply:

85 to 264 VAC / 47 to 63 Hz; Option: 115 VAC / 60 Hz

Analogue outputs:

4–20 mA (one output per measured component)

Digital outputs:

12 units / functions, such as status signals, limit alarms, configurable measuring point switching

Digital inputs:

4 units / functions

Data storage:

with history function of approximately 6,500 values; output via RS 232; also readable on the display

Interfaces:

RS 232, digital output of the measured values and program updates; Option: Profibus DP / CAN-bus

Further specifications

on request

Technical Details

Measuring ranges:

CH₄: 0 to 100 Vol.%, CO₂: 0 to 100 Vol.%, O₂: 0 to 25 Vol.%, H₂S: 0 to 5,000 ppm, others on request

Designs for the detection of different gases possible:

SSM 6000 Classic (CH₄, H₂S), SSM 6000 Classic (CH₄, H₂S, O₂), SSM 6000 Classic (CH₄, H₂S, O₂, CO₂)

Wall construction

or table housing 19”/3 height units, sub-racks 84 partial units

Display and measured value displays:

4-digit LED display of measured values, status indicators for each reading, 4-digit illuminated LCD for each measured value

Power supply:

85 to 264 VAC / 47 to 63 Hz; Option: 115 VAC / 60 Hz

Analogue outputs:

4–20 mA (one output per measured component)

Digital outputs:

12 units / functions, such as status signals, limit alarms, configurable measuring point switching

Digital inputs:

4 units / functions

Data storage:

with history function of approximately 6,500 values; output via RS 232; also readable on the display

Interfaces:

RS 232, digital output of the measured values and program updates; Option: Profibus DP / CAN-bus

Further specifications

on request

Features

The version for hot region (+50 °C).

High quality measurement components and methods:

an infra-red measuring process is used to detect methane (CH₄) and carbon dioxide (CO₂) with high accuracy and selectivity. This process eliminates any dependencies that pressure and temperature could have on the measured values;

hydrogen sulphide (H₂S) and hydrogen (H₂) are detected by electrochemical sensors;

oxygen (O₂) is predominantly measured using electrochemical sensors. Paramagnetic measuring cells are used for special requirements – particularly in conjunction with upgrading biogas to biomethane so that it can be used to supply the public grid.

Excellent long-term stability during methane and carbon dioxide measurements ensured by special technology.